How does Battery Energy Storage Systems (BESS) work?

2025-06-04

Battery Energy Storage Systems (BESS) is fast becoming an integral component of the modern power infrastructure. By storing electrical energy when it is available in abundance (or at low price) and releasing it when there is high demand or price, BESS mitigates volatility, increases reliability, and provides valuable services to the grid. Here, we go in-depth into the fundamental elements of a BESS, charging and discharging operations, control structure, and how they all come together to form a safe, reliable, and efficient energy storage product.

1. What Is a BESS?

Essentially, a Battery Energy Storage System is a series of battery modules, power electronics, and intelligent control units which store electricity as chemical energy and discharge the same as electricity when and where it is required. Compared to a conventional diesel generator or pumped-hydro plant, a BESS is compact, highly responsive (milliseconds to switch modes), and can be installed in nearly any location which has adequate space and access to the grid.

In total, a BESS will consist of the following:

  1. Battery Modules
  2. Battery Management System (BMS)
  3. Power Conversion System (PCS)
  4. Energy Management System (EMS) / Central Control
  5. Balance-of-System (BOS) Components (HVAC, protection devices, auxiliary panels)

All of these components allow the BESS to act as an aggregation of numerous "rechargeable battery banks" that get charged from and dumped to the grid, renewables, or local loads based on real-time demand.

bess structure diagram

2. Key Components & Their Functions

This section breaks down the main hardware and software elements of a typical BESS.

2.1 Battery Chemistries & Modules

  • Battery Cell: The atomic unit of storage. Modern BESS virtually always come with lithium-ion chemistries—most commonly Lithium Iron Phosphate (LiFePO₄) or variants of Nickel-Cobalt-Manganese (NCM, NCA), although other technologies (e.g., sodium-ion, flow batteries) are beginning to emerge.
  • Battery Module or Pack: Several individual cells are packaged and connected together into a module or "pack," typically designed for a given voltage (e.g., 51.2 V, 280 Ah) and energy (Wh) capacity. Modules may be connected in series and parallel to create higher-voltage strings or larger-capacity racks.
  • Battery Rack / Cluster: Several modules or packs are stacked upon each other to form a rack. In large-scale installations, dozens or hundreds of racks (each with dozens or hundreds of modules) cluster or containerized units to reach the megawatt‐hour (MWh) level.

Chemistry Comparison (LiFePO₄ vs. NCM):

Parameter NCM (Ni-Co-Mn) LiFePO₄
Theoretical Capacity > 250 mAh/g ~ 170 mAh/g
Nominal Voltage ~ 3.6 V ~ 3.2 V
Energy Density (Wh/kg) ~ 249 Wh/kg ~ 135 Wh/kg
Cycle Life > 3,000 cycles (at ~80 % DoD) > 5,000 cycles (at ~80 % DoD)
Safety / Thermal Stability Lower (thermal event ~220 °C) Higher (stable to > 1,000 °C)
Cost Higher Lower

As LiFePO₄ cells offer superior thermal stability and longer cycle life (although at comparatively lower energy density), the majority of large-scale BESS applications select LiFePO₄, especially where long life and safety are foremost.

2.2 Battery Collection Panel (BCP)

In between the battery racks and the power electronics is the Battery Collection Panel (BCP). Similar in structure to a PV combiner box, the BCP collects DC outputs from two or more battery racks (or modules), provides fusing/protection, and distributes the summed-up DC power to the Power Conversion System. In return, it also distributes DC charging current from the PCS back to the right battery strings.

2.3 Power Conversion System (PCS)

Broadly called the "heart" of a BESS, the PCS contains bidirectional inverters (and sometimes also a step-up transformer) to perform two fundamental functions:

Rectifier Mode (AC → DC): Under charge, the PCS receives AC power (from the grid or in-house generator/alternative source), converts it to DC, and supplies the appropriate voltage/current to charge the battery.

Inverter Mode (DC → AC): In discharging, the PCS charges stored DC energy as grid-synchronized AC, synchronized for voltage, frequency, and phase, before it is sent out.

A well-engineered PCS achieves modern efficiencies of approximately 97–98 % per conversion stage (i.e., AC→DC or DC→AC). As a BESS must naturally convert twice (once to DC for charging, once to AC for discharging) its round-trip efficiency (RTE) will generally be between 85 % to 90 %.

2.4 Battery Management System (BMS)

The BMS accomplishes the following:

Cell-Level Monitoring: Constant monitoring of each cell's voltage and temperature.

  • State-of-Charge (SOC) & State-of-Health (SOH) Estimation: Using algorithms to estimate the extent to which each cell or module is "full" and its remaining usable capacity over time.
  • Cell Balancing: Keeping all series cells at very similar voltages. Unbalance can lead some cells to overcharge or overdischarge, accelerating degradation, or even safety events.
  • Safety Protections: Supervising over-voltage, under-voltage, over-current, over-temperature, etc., fault modes. Consequently, the BMS can stop charging/discharging to prevent damage or activate emergency procedures (e.g., module disconnect).
  • Communication: Communicating data and commands with the Energy Management System (EMS) or Central Control (in most instances, simply called the MGCC, or Microgrid Central Controller).

BMS architectures are multi-level as well:

  • BMU (Battery Module Monitoring Unit): Guards a few cells per module.
  • BCU (Battery Cluster Control Unit): Aggregates data from greater than one BMU within a single rack or cluster.
  • BSU (Battery Stack Control Unit): Controls multiple BCUs to represent a large "stack" of cells as a single unit.
  • SCU (System Site Control Unit): The top-level unit that sends messages to the EMS, translating high-level directives (e.g., 80 % SOC charge) to module-level directives.

2.5 Energy Management System (EMS) / Central Control

Whereas the BMS attends to cell-level performance and safety, the EMS (or MGCC) are the "brains" responsible for decision-making:

  • When to Charge / Discharge: Depending on price signals (time-of-use tariffs, ancillary market bids), forecasted renewables, user-programmed schedules, or grid operator commands.
  • How Much to Charge / Discharge: Establishing limits of power (kW) and depth-of-discharge (e.g., avoid dropping below 20 % SOC).
  • Which Operating Mode to Use: Choosing between grid-connection arbitrage, peak shaving, renewable smoothing, frequency regulation, or islanded backup modes.
  • Health & Lifespan Optimization: Implementing strategies such as cycling 20–80 % SOC instead of 0–100 % to increase battery life or limiting charge voltage for reducing stress.

In essence, the EMS accepts real-time inputs (weather forecast, grid frequency, local load, market price) and commands the PCS and BMS sequentially to maximize revenue, reliability, or lifespan.

2.6 Balance-of-System (BOS) Equipment

Apart from battery racks, BMS, and PCS, a commercial BESS also consists of:

  • HVAC / Thermal Management: It is essential to maintain a safe working temperature (typically 15–35 °C for Li-ion). Air-cooled or liquid-cooled solutions manage airflow over racks; large installations will typically require industrial chillers, ducting, or cold-plate cooling.
  • Fire Detection & Suppression: Because lithium-ion has the potential for thermal runaway to accumulate very rapidly, BESS containers typically have smoke detectors, gas sensors, and clean-agent (or water mist) suppression systems.
  • Protection Equipment: Surge arresters, circuit breakers, fuses, and busbar systems with fault-isolation and short-circuit avoidance.
  • Transformers & Switchgear: An inverter output (400 V or 690 V AC) is stepped-up by a transformer to MV (e.g., 10 kV or 35 kV) for grid connection in MV systems, especially. Switchgear and protective relays ensure safe grid synchronisation.
  • Auxiliary Panels: Provide standby power to BAS (Building Automation System), BMS, and other low-power loads.
  • Monitoring & SCADA Interfaces: Facilitate monitoring of system status, alarms, performance indicators by remote operators and grid operators, and initiate dispatch commands.

 

3. Charging & Discharging: Step by Step

3.1 The Charging Process

  1. External Signal or Schedule: The EMS is prompted to charge—this could be a time-of-use rate reduction during nighttime, excess on-site solar in mid-day, or a frequency regulation instruction from the ISO.
  2. PCS Switches to Rectifier Mode: The PCS receives AC from the grid (or on-site generator/inverter) and charges it to DC.
  3. BCP & DC Cabling: The DC output is distributed through the Battery Collection Panel (BCP), and then fed into each battery rack.
  4. BMS Active Balancing & Monitoring: The BMS monitors the cell voltages. In early stages (0–80 % SOC), charging is constant-current (CC). When cells approach their upper voltage limit, the BMS (through the PCS) switches to constant-voltage (CV) mode, limiting current to avoid over-voltage stress.
  5. Temperature Control: HVAC systems maintain cell temperatures within the ideal range. Heat generated by internal resistance is dissipated.
  6. State-of-Charge Ramping: Batteries are charged up to a specific cutoff voltage (e.g., 3.65 V for each LiFePO₄ cell) or until an upper SOC (e.g., 90 %) is achieved. The BMS then instructs the PCS to reduce or stop charging to avoid overcharge.

3.2 The Discharging Process

  1. Discharge Trigger: EMS directs a discharge—e.g., during peak evening load to avoid costly grid prices, for grid support (ancillary services), or for serving critical loads in the event of a loss.
  2. BMS Verification: The BMS checks cell voltages, SOC (should be greater than minimum, e.g., 20 %), and temperatures (should be within safe levels).
  3. PCS operates in inverter mode: DC power stored is transformed into AC. Inverter synchronizes with grid voltage/frequency (50 Hz or 60 Hz, depending on the region), thus maintaining phase alignment for seamless power injection.
  4. Power Delivery: The inverter supplies AC to on-site loads, local microgrid, or to the grid at large. If islanded (off-grid backup), a transfer switch switches off the BESS from the grid; the inverter "black starts" and supplies critical circuits.
  5. Depth-of-Discharge Management: When the battery achieves a programmed DOD level (e.g., 80 %), the BMS alerts the EMS/PCS to slow down or cut off discharge, saving life and creating a reserve buffer.

3.3 Round-Trip Efficiency

Round-Trip Efficiency (RTE) = (Energy Delivered on Discharge) / (Energy Taken In During Charge) × 100%.

A typical LiFePO₄ BESS achieves ~ 90 % RTE. Losses due to:

  • Inverter/Rectifier Losses: ~ 2–3 % in each direction.
  • Internal Resistive Losses: Ohmic heating due to current passing through cells and busbars.
  • Transformers & Cabling: If transformer and cable losses are added when stepping up to MV levels, a few percent.
  • Auxiliary Cooling & Control: BMS electronics, fan motors, and HVAC compressers consume power, particularly during heavy cycling or high temperatures.

bess internal structure

4. Control Architecture & Operational Modes

4.1 Hierarchical Control Layers

  1. BMU / BCU / BSU (Module & Cell Level): Control high-speed protection features (overcurrent, overvoltage, temperature alarms), cell balancing and low-level SOC/SOH calculation.
  2. SCU (Site-Level Supervisory): Compiles module and rack information. Reports pack SOC and temperature and triggers aggregate alarms. Communicates directly with EMS.
  3. EMS / MGCC (Plant-Level Controller): The business logic layer that performs strategies—arbitrage, peak shaving, frequency response, or islanded backup. Serves real-time setpoints (e.g., "discharge at 2 MW until SOC = 30 %") to the SCU/PCS.
  4. Remote Operator / EMS Portal: Allows human operators and site engineers to schedule maintenance, query historical performance, or override automatic controls manually in case of emergencies.

4.2 Common Operating Modes

Time-of-Use Arbitrage

Charge at low electric rates (typically at night).

Discharge on peak days when rates are high.

EMS continually monitors price signals from the ISO or utility and makes optimal charge/discharge based on battery limits (DoD, SOC window).

Peak Shaving / Demand Charge Reduction

Industrial or commercial customers are charged exorbitant demand charges for their all-time peak kW usage during an interval window.

BESS is precharged and operates in local facility peaks, effectively shaving the measured peak.

The result: near-instant ROI through lowering monthly utility bills.

Renewable Smoothing & Firming

Solar and wind generation can be extremely volatile.

BESS charges during surprise production surges (e.g., cloud breaks at noon) and discharges for deficits (approaching clouds or periods of wind slowing).
This "firmed" output appears more predictable to the grid operator, reducing the risk of curtailment and increasing plant economics.

Black Start & Backup Power

In the event of a utility failure, a BESS can transition from grid-bound to islanded mode in milliseconds.

Sensitive loads (telecom facilities, data centers, hospitals) see uninterrupted power, with the battery bridging the gap until the backup generator or grid takes over.

BESS offers faster response and zero emissions at the point of use compared to diesel generators.

Frequency Regulation & Ancillary Services

Grid operators acquire fast-reacting resources to balance frequency deviations (e.g., when generation and load do not match).

A BESS can draw (charge) or supply (discharge) power within less than a second, assisting in keeping grid frequency at 50 Hz or 60 Hz.

In most markets, these ancillary services command a premium—sometimes greater than pure energy arbitrage—making frequency regulation a substantial revenue source.

Voltage Support & Reactive Power

Certain inverters have the capability to supply reactive power (vars) to assist with voltage profile management on distribution feeders, which increases voltage stability and losses.

Although not "real power" delivery, voltage support is a further grid‐service possibility for sophisticated BESS installations.

5. Performance Metrics & Lifespan Factors

5.1 State of Charge (SOC) & Depth of Discharge (DoD)

SOC (State of Charge): Displays the amount of battery capacity available as a percentage of full capacity (0 % to 100 %).

DoD (Depth of Discharge): Reports measuring amount of energy withdrawn relative to battery's capacity (e.g., 80 % DoD = 80 % of energy stored extracted).

Cycling is typically restricted by BESS operators to a limited range (e.g., 20–80 % SOC) in order to reduce stress and enhance cycle life.

5.2 Cycle Life & Calendar Life

Cycle Life: The number of charge/discharge cycles that a battery can undergo before its capacity drops to a specified level (typically 80 % original capacity). In LiFePO₄, this could be greater than 5,000 at 80 % DoD.

Calendar Life: Regardless of whether cycled infrequently, batteries will degrade over time due to chemical side reactions. Li-ion calendar life can be 10–15 years, depending on SOC and temperature.

Manufacturers usually define the "useful life" as the lesser of calendar life or cycle life. For instance, if a lithium-ion pack is 80% capacity at 6,000 cycles or at 15 years, whichever occurs first, that is end-of-life (EOL).

5.3 Efficiency & Self-Discharge

Round-Trip Efficiency (RTE): Typically 85–90 % for Li-ion BESS. That is, for every 1 MWh stored, only 0.85–0.90 MWh can be regained after accounting for losses in inverters, battery, and auxiliaries.

Self-Discharge: In stand-by, a battery gradually loses charge. At normal ambient temperatures (25 °C), a LiFePO₄ cell will self-discharge by ~ 0.4 % capacity per month. Higher temperatures accelerate this loss (for example, at 45 °C, self-discharge could be up to 1.5 % per month).

5.4 Guaranteed Power Capacity (GPC)

GPC: The minimum power the BESS is able to deliver continuously at its point of interconnection over its warranted life (e.g., "retain ≥90 % of rated power for 10 years").

Project owners usually swap a GPC guarantee to ensure the system won't fall below some output, protecting revenue streams.

6. Safety & Thermal Management

6.1 Thermal Control

Batteries operate optimally within a narrower temperature range—typically 15–35 °C for Li-ion. Outside of this, degradation is accelerated or safety is jeopardized.

Air-Cooled Systems: Employ fans or HVAC to force conditioned air across battery racks. Less complicated, but could lag behind under hot ambient conditions.

Liquid-Cooled Systems: Employ coolant plates or cold plates in direct contact with the module, offering more stable temperature control, especially for higher power or high-density racks.

6.2 Fire & Gas Detection

Smoke Detectors & Gas Sensors: Lithium-ion cells will release combustible gases during thermal runaway. Forewarning is critical.

Automatic Suppression: Most large BESS containers use clean-agent suppression (e.g., Novec 1230 or FM-200) or water-mist systems, carefully designed to quickly extinguish cell fires without damage to other equipment.

Compartmentalization: Battery racks are typically separated into thermal zones. When one module overheats, design and firewalls arrest propagation.

6.3 Electric Protections

Fuses & Circuit Breakers: Protect against overcurrent or short circuit in DC cabling.

Surge Arresters: Protect against lightning or grid surges on AC side.

Isolation Switches: Enable safe maintenance by de-energizing battery strings or inverter.

bess container

7. Real-World BESS Configurations

7.1 Containerized BESS

Standard 20- or 40-ft ISO Containers: Often pre-assembled with battery racks, HVAC units, fire suppression, PCS inverters, and a small control room.

Modular Strategy: Multiple containers may be "stacked" or installed side-by-side to meet desired capacity (e.g., 5 MW/20 MWh might use four 20-ft containers, each 1.25 MW/5 MWh).

Generic Project Schedule: Contract through delivery is ~ 4–5 months for a 50 MWh system. Containers are shipped to site almost turnkey with only local commissioning, grid connection, and minimal civil works required.

7.2 Station-Built (Plant-Style) BESS

Custom Facility: Battery racks, inverters, transformers, and power-control rooms are housed within a specially built building ("station house").

Higher Upfront CapEx: Generally used for very large utility-scale applications (> 100 MWh) where economies of scale are feasible in building a permanent facility.

Longer Construction Time: Includes site grading, foundation, HVAC ductworks, and more sophisticated safety systems.

8. Cost Breakdown & Trends

8.1 Cost Components

A typical 1 C (four-hour) energy-type BESS cost breakup (2024 figures) per kWh may be:

Battery Cells / Modules: 60–70 % of total system cost

PCS (Inverter + Transformer) & Power Cabling: 20–25 %

Balance-of-Plant (EMS, BMS, HVAC, Labor, Civil): 10–15 %

Example Cost Trends (2018–2025 Projections):

Year Battery Module Cost (USD/kWh) PCS & Transform Cost (USD/kW) EMS Cost (USD/kWh)
2018 270 70 60
2019 245 60 60
2020 220 60 60
2021 195 60 60
2022 171 60 60
2023 146 60 60
2024 121 60 60
2025 96 60 60

Because high-power application requires more PCS capacity than battery energy, a 0.5 C (power-type) BESS would cost around 550–600 USD/kWh of the overall system cost, and a 1 C (energy-type) system would be around 370 USD/kWh in current bids.

8.2 Market Outlook

By 2050, global cumulative BESS installations will be 1,676 GW / 5,827 GWh as a result of declining battery prices (BESS CapEx has fallen by about 80 % since 2010), supportive policies, and the rapid rollout of renewables. China, the U.S., and India together will account for ~ 36 % of global deployment through the middle of the century.

9. Typical Applications & Use Cases

Utility-Scale Co-Location with Renewables:

Scenario: A 100 MW solar farm installs a 50 MW/200 MWh BESS.

Benefit: The BESS absorbs midday solar surplus, and charges out to the grid during peak evening. It also offers frequency regulation, with additional revenue.

Commercial & Industrial (C&I) Peak Shaving:

Scenario: A factory installs a 2 MW/4 MWh BESS.

Benefit: By shedding load when internal load is high, the plant reduces its peak demand from the utility (typically a top-five 15-minute block per billing cycle), reducing demand charges. The BESS may pay for itself in 3–4 years.

Residential & Microgrid Backup:

Scenario: A homeowner installs a 10 kW/20 kWh battery to accompany an existing 10 kW rooftop PV array.

Benefit: Extra daytime sun charges the battery; during the nighttime, the battery supplies vital loads (lights, refrigerator, some HVAC), reducing grid consumption by around 50 %. When there is a blackout, the battery provides immediate backup for essential circuits.

Ancillary Services & Frequency Regulation:

Scenario: A 20 MW BESS bids into the frequency regulation market.

Benefit: Because the BESS accelerates from charge to discharge (and from discharge to charge) within less than 1 second, it is better than conventional resources in following AGC (Automatic Generation Control) signals. Regulation services revenues can be more than simple energy arbitrage strategies.

10. Summary & Key Takeaways

  1. Modular Design: A BESS is composed of battery cells → modules → racks/clusters → containers or station buildings.
  2. Two-Way Power Flow: AC⇌DC conversion is handled by the Power Conversion System (PCS); cell balancing and safety are ensured by the Battery Management System (BMS).
  3. Smart Control: Energy Management System (EMS) is optimized when and how the BESS charges/discharges—application from arbitrage to grid support to backup power.
  4. Efficiency & Lifespan: 85–90 % round-trip efficiency for new lithium-ion BESS. Coupled with effective thermal management and partial SOC cycling (e.g., 20–80 %), cycle life can reach thousands of cycles (5,000+ for LiFePO₄).
  5. Safety First: Multi-level BMS, fire detection/suppression, and efficient HVAC systems keep batteries within safe thermal/electrical operating ranges.
  6. Applications Everywhere: From utility-scale solar firming through industrial demand charge reduction to residential backup through frequency regulation markets, BESS flexibility is unparalleled.
  7. Cost Savings & Scaling: The cost of battery modules has come down from ~$270/kWh in 2018 to under $100/kWh by 2025, enabling rapid global deployment.

Fundamentally, a Battery Energy Storage System is a highly integrated marriage of state-of-the-art power electronics, high-performance battery chemistry, thermal and safety equipment, and intelligent software controls that all work together to shift energy in time, stabilize the grid, and enhance the reliability of power delivery. As cost drops further and control algorithms become more sophisticated, BESS will play an ever greater role in the decarbonization of energy systems everywhere.